Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 43
Filter
2.
Fetal Diagn Ther ; 51(1): 1-6, 2024.
Article in English | MEDLINE | ID: mdl-37778343

ABSTRACT

INTRODUCTION: The measurement of nuchal translucency (NT) is crucial for assessing risk of aneuploidies in the first trimester. We investigate the ability of NT assessed by a transverse view of the fetal head to detect fetuses at increased risk of common aneuploidies at 11-13 weeks of gestation. METHODS: We enrolled a nonconsecutive series of women who attended our outpatient clinic from January 2020 to April 2021 for aneuploidy screening by means of a first trimester combined test. All women were examined by operators certified by the Fetal Medicine Foundation. In each patient, NT measurements were obtained both from the median sagittal view and transverse view. We calculated the risk of aneuploidy using NT measurements obtained both with sagittal and axial scans, and then we compared the results. RESULTS: A total of 1,023 women were enrolled. An excellent correlation was found between sagittal and transverse NT measurements. The sensitivity and specificity of the axial scan to identify fetuses that were deemed at risk of trisomy 21 using standard sagittal scans were 40/40 = 100.0% (95% confidence interval [CI]: 91.2-100.0) and 977/983 = 99.4% (95% CI: 98.7-99.7), respectively. The sensitivity and specificity of the axial scan to identify fetuses at risk of trisomy 13 or 18 were 16/16 = 100.0% (95% CI: 80.6-100.0) and 1,005/1,007 = 99.8% (95% CI: 99.3-99.9). CONCLUSIONS: When the sonogram, a part of combined test screening, is performed by an expert sonologist, axial views can reliably identify fetuses at increased risk of trisomies without an increase in false negative results.


Subject(s)
Trisomy , Ultrasonography, Prenatal , Pregnancy , Female , Humans , Trisomy/diagnosis , Trisomy/genetics , Pregnancy Trimester, First , Ultrasonography, Prenatal/methods , Aneuploidy , Nuchal Translucency Measurement/methods , Fetus/diagnostic imaging , Maternal Age
3.
Am J Obstet Gynecol MFM ; 5(12): 101198, 2023 12.
Article in English | MEDLINE | ID: mdl-37866717

ABSTRACT

BACKGROUND: Agenesis of the corpus callosum is associated with several malformations of cortical development. Recently, features of focal cortical dysgyria have been described in fetuses with agenesis of the corpus callosum. OBJECTIVE: This study aimed to describe the "cortical invagination sign," a specific sonographic feature of focal cortical dysgyria, which is consistently seen at midtrimester axial brain ultrasound in fetuses with complete agenesis of the corpus callosum. STUDY DESIGN: This was a retrospective analysis of prospectively collected data from 2018 to 2021, including patients referred to 5 fetal medicine centers in the second trimester of pregnancy (19 0/7 to 22 0/7 weeks of gestation) with suspected complete agenesis of the corpus callosum. All cases with the diagnosis of complete agenesis of the corpus callosum were submitted to an axial sonographic assessment of the fetal brain on the transventricular plane. In this scanning section, the mesial profile of both cerebral hemispheres at the level of the frontal-parietal cortex was investigated. In this area, the operator looked for an abnormal invagination of the cortical surface along the widened interhemispheric fissure, which was referred to as the "cortical invagination sign." All fetuses were submitted to dedicated antenatal magnetic resonance imaging to reassess the ultrasound findings. Cases with additional brain anomalies, which did not involve the cortex, were excluded. The final diagnosis was confirmed at postnatal brain magnetic resonance imaging or postmortem examination, for cases undergoing termination of pregnancy. The primary outcome of this study was to evaluate the presence and laterality of the "cortical invagination sign" in fetuses with complete agenesis of the corpus callosum at antenatal ultrasound and magnetic resonance imaging. RESULTS: During the study period, 64 cases of complete agenesis of the corpus callosum were included; of those cases, 50 (78.1%) resulted in termination of pregnancy, and 14 (21.9%) resulted in a live birth. The "cortical invagination sign" was detected at ultrasound in 13 of 64 cases (20.3%) and at targeted brain magnetic resonance imaging in 2 additional cases (23.4%), all of which were electively terminated. Moreover, the "cortical invagination sign" was found to be exclusively unilateral and on the left cerebral hemisphere in all the cases. There was a predominant number, although nonsignificant, of male fetuses (80.0% of cases; P=.06) in the group of complete agenesis of the corpus callosum with the "cortical invagination sign." CONCLUSION: The "cortical invagination sign" is a specific marker of focal cortical dysgyria, which seems to characterize at midtrimester of pregnancy in a large group of fetuses with complete agenesis of the corpus callosum. The etiology, pathophysiology, and prognostic significance of this finding remain to be elucidated.


Subject(s)
Agenesis of Corpus Callosum , Corpus Callosum , Pregnancy , Humans , Male , Female , Corpus Callosum/diagnostic imaging , Corpus Callosum/pathology , Pregnancy Trimester, Second , Agenesis of Corpus Callosum/diagnostic imaging , Agenesis of Corpus Callosum/pathology , Prenatal Diagnosis , Retrospective Studies , Ultrasonography, Prenatal/methods , Gestational Age , Fetus
5.
J Hypertens ; 41(8): 1333-1338, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37260263

ABSTRACT

OBJECTIVE: Preeclampsia is one of the most severe diseases among the hypertensive disorders of pregnancy (HDP) and the leading cause of maternal and fetal morbidity and mortality. It is of crucial importance to early identify women at a high risk for preeclampsia to implement appropriate preventive strategies. In our study, we aimed to test the hypothesis that serum uric acid to creatinine ratio (SUA/sCr) is related to the development of preeclampsia and maternal and neonatal complications. METHODS: We searched for uric acid and creatine values in the medical records of 269 women who consecutively attended our HDP Clinic from December 2018 to December 2022. We compared the baseline characteristics of participants with normotensive pregnancy ( n  = 57), to those with HDP without preeclampsia (HDP-non-PE) ( n  = 100) and those with preeclampsia ( n  = 112), and we performed adjusted logistic regression analysis to test the associations between SUA/sCr and the development of preeclampsia and maternal and neonatal complications. RESULTS: SUA/sCr was consistently higher in women with preeclampsia in all trimesters of pregnancy. Higher SUA/sCr at the third trimester was associated with an increased odd of developing preeclampsia [odds ratio (OR) 1.29, confidence interval (CI) 1.15-1.50, P  = 0.001], preterm birth (OR 1.23, CI 1.05-1.45, P  = 0.011), and composite neonatal outcome (OR 1.33, CI 1.12-1.59, P  = 0.001), after adjustment for age, BMI before pregnancy, nulliparity, antihypertensive therapy, and acetylsalicylic acid therapy during pregnancy. CONCLUSIONS: Having higher SUA/sCr during pregnancy is associated with the development of PE and adverse pregnancy outcomes. Controlled prospective studies are warranted to clarify the predictive power of this novel marker during pregnancy.


Subject(s)
Hypertension, Pregnancy-Induced , Pre-Eclampsia , Premature Birth , Pregnancy , Infant, Newborn , Female , Humans , Pregnancy Outcome , Uric Acid , Creatinine
6.
Article in English | MEDLINE | ID: mdl-37162492

ABSTRACT

BACKGROUND: Women with unfavorable obstetric history can benefit from prophylactic cerclage ("history indicated") which can be performed vaginally or transabdominally with laparoscopic techniques. The aim of our study is to evaluate the effectiveness in the prevention of preterm birth of the vaginal technique and of the minimally invasive laparoscopic technique in women with an unfavorable obstetric history. METHODS: This was a retrospective cohort study examining elective cerclages performed in women with adverse obstetrics history. The primary outcome was rate of early preterm and second trimester deliveries while other outcomes analyzed were surgical complications, the time needed for cerclage procedures, live birth rate, gestational age at delivery, birth weight, Apgar score. RESULTS: Data from 64 women were analyzed; among them, 14 underwent a laparoscopic procedure (22%) while 50 a vaginal cerclage (78%). The two groups were homogeneous in terms of demographic characteristics, but of course differed significantly in terms of obstetrics history, as well as for the surgical indications of cerclage procedures. The rate of early preterm deliveries and second trimester miscarriage were the same in the vaginal and laparoscopic group (8%), comparable to what was reported in literature. The operative time was longer in the laparoscopic group, but with similar duration of the hospital stay. We reported no intraoperative complications in both groups. CONCLUSIONS: As the laparoscopic procedure, usually reserved for women with a previous failed vaginal cerclage, has been proved to be equally safe and effective, it may could be proposed to a wider group of women. Prospective randomized studies are needed to provide new and conclusive data about this topic.

7.
J Matern Fetal Neonatal Med ; 36(1): 2197099, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37031967

ABSTRACT

We report the case of a massive fetal cardiac rhabdomyoma recently occurred at our clinic. A woman at 23 weeks of gestational age was referred to our center for a fetal cardiac echogenic mass of 26 mm detected at the second-trimester screening ultrasound. During pregnancy, though, the mass progressively increased its dimensions until reaching 48 mm in diameter at 37 weeks of gestation. Fetal echoencephalography and brain magnetic resonance did not show any further fetal anomalies, but molecular genetic testing at amniocentesis revealed a heterozygotic missense variant of gene TSC2 associated with Tuberous Sclerosis. The mass was therefore most likely preferable to a single large rhabdomyoma of gradually increasing dimensions. The baby was delivered at term with a cesarean section. Because of the rhabdomyoma remarkable size and newborn ECG electrical alterations, postnatal therapies with Flecainide and Everolimus were started. Everolimus treatment led to a significant and progressive reduction in the cardiac mass volume. This case, therefore, shows the efficacy of what seems to be a promising treatment in pediatric patients with large rhabdomyomas.Learning points:Rhabdomyomas may present with different features: most often they appear as multiple masses along the interventricular sept, but they may also appear as a single large thoracic mass.When a rhabdomyoma is suspected, genetic counseling is recommended.Both before and after birth, a multidisciplinary approach is useful to choose the appropriate therapy for the newborn.mTOR inhibitors therapies look like promising therapeutic approaches to stimulate the involution of rhabdomyomas.


Subject(s)
Heart Neoplasms , Rhabdomyoma , Tuberous Sclerosis , Infant , Infant, Newborn , Humans , Pregnancy , Child , Female , Rhabdomyoma/diagnostic imaging , Rhabdomyoma/genetics , Rhabdomyoma/complications , Everolimus , Cesarean Section , Ultrasonography , Tuberous Sclerosis/complications , Tuberous Sclerosis/diagnostic imaging , Tuberous Sclerosis/genetics , Heart Neoplasms/diagnostic imaging , Heart Neoplasms/therapy , Heart Neoplasms/complications
8.
Acta Obstet Gynecol Scand ; 102(6): 744-750, 2023 06.
Article in English | MEDLINE | ID: mdl-37059118

ABSTRACT

INTRODUCTION: The objective of this study was to describe a cohort of fetuses with an ultrasound prenatal diagnosis of obliterated cavum septi pellucidi (oCSP) with the aim to explore the rate of associated malformations, the progression during pregnancy and the role of fetal magnetic resonance imaging (MRI). MATERIAL AND METHODS: This was a retrospective multicenter international study of fetuses diagnosed with oCSP in the second trimester with available fetal MRI and subsequent ultrasound and/or fetal MRI follow-up in the third trimester. Where available, postnatal data were collected to obtain information on neurodevelopment. RESULTS: We identified 45 fetuses with oCSP at 20.5 weeks (interquartile range 20.1-21.1). oCSP was apparently isolated at ultrasound in 89% (40/45) and fetal MRI found additional findings in 5% (2/40) of cases, including polymicrogyria and microencephaly. In the remaining 38 fetuses, fetal MRI found a variable amount of fluid in CSP in 74% (28/38) and no fluid in 26% (10/38). Ultrasound follow-up at or after 30 weeks confirmed the diagnosis of oCSP in 32% (12/38) while fluid was visible in 68% (26/38). At follow-up MRI, performed in eight pregnancies, there were periventricular cysts and delayed sulcation with persistent oCSP in one case. Among the remaining cases with normal follow-up ultrasound and fetal MRI findings, the postnatal outcome was normal in 89% of cases (33/37) and abnormal in 11% (4/37): two with isolated speech delay, and two with neurodevelopmental delay secondary to postnatal diagnosis of Noonan syndrome at 5 years in one case and microcephaly with delayed cortical maturation at 5 months in the other. CONCLUSIONS: Apparently isolated oCSP at mid-pregnancy is a transient finding with the visualization of the fluid later in pregnancy in up to 70% of cases. At referral, associated defects can be found in around 11% of cases at ultrasound and 8% at fetal MRI indicating the need for a detailed evaluation by expert physicians when oCSP is suspected.


Subject(s)
Clinical Relevance , Microcephaly , Female , Pregnancy , Humans , Ultrasonography, Prenatal/methods , Magnetic Resonance Imaging/methods , Fetus/abnormalities , Retrospective Studies , Magnetic Resonance Spectroscopy
10.
J Matern Fetal Neonatal Med ; 36(1): 2198063, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37019628

ABSTRACT

BACKGROUND: Hypertensive disorders of pregnancy and fetal growth restriction share common etiopathological origins and could be caused by maternal hemodynamic maladaptation to pregnancy. OBJECTIVE: The aim of our study is to evaluate if there is a correlation between maternal hemodynamic detected by UltraSonic Cardiac Output Monitor (USCOM®) during the first trimester and the pregnancy outcome. STUDY DESIGN: We recruited a nonconsecutive series of women in the first trimester of pregnancy with no previous history of hypertensive disorders. We measured the pulsatility index uterine arteries and performed a hemodynamic evaluation by USCOM® device. After delivery, we reported the development of hypertensive disorders or intrauterine fetal growth restriction later during gestation. RESULTS: A total of 187 women were enrolled during the first trimester; 17 (9%) developed gestational hypertension or preeclampsia while 11 (6%) delivered a restricted growth fetus. Mean uterine artery pulsatility index above the 95th percentile was significantly more frequent in both women who developed hypertension and those with fetal growth restriction compared to controls. Hemodynamic parameters (reduced cardiac output and increased total vascular resistance) were significantly different in the group that developed hypertensive disorders, compared to uncomplicated pregnancy. ROC curves demonstrated the usefulness of uterine artery pulsatility index in the prediction of fetal growth restriction, while hemodynamic parameters were significantly associated to the development of hypertensive disorders. CONCLUSIONS: Hemodynamic maladaptation to pregnancy may predispose to the development of hypertension, while we demonstrated a significative relationship between growth restriction and mean uterine pulsatility index. Further studies are needed to assess the value of hemodynamics evaluation in screening protocols of preeclampsia.


Subject(s)
Hypertension, Pregnancy-Induced , Pre-Eclampsia , Pregnancy , Female , Humans , Pregnancy Trimester, First , Pre-Eclampsia/diagnosis , Fetal Growth Retardation , Hemodynamics , Pregnancy Outcome , Uterine Artery
11.
J Clin Med ; 12(4)2023 Feb 19.
Article in English | MEDLINE | ID: mdl-36836188

ABSTRACT

Grayscale abdomen ultrasound (US) is routinely performed in pregnant women with suspected pregnancy-related liver dysfunction, but its diagnostic yield is very low. We aimed to investigate the association between Doppler-US findings, liver stiffness measurement (LSM) and different causes of pregnancy-related liver dysfunction. This is a prospective cohort study of pregnant women referred to our tertiary center for any suspected gastrointestinal disease between 2017 and 2019 and undergoing Doppler-US and liver elastography. Patients with previous liver disease were excluded from the analysis. For group comparisons of categorical and continuous variables, the chi-square test or Mann-Whitney test, and the McNemar test were used, as appropriate. A total of 112 patients were included in the final analysis, of whom 41 (36.6%) presented with suspected liver disease: 23 intrahepatic cholestasis of pregnancy (ICP), six with gestational hypertensive disorders and 12 cases with undetermined causes of elevated liver enzymes. Values of LSM were higher and significantly associated with a diagnosis of gestational hypertensive disorder (AUROC = 0.815). No significant differences at Doppler-US or LSM were found between ICP patients and controls. Patients with undetermined causes of hypertransaminasemia showed higher hepatic and splenic resistive indexes than controls, suggesting splanchnic congestion. The evaluation of Doppler-US and liver elastography is clinically useful in patients with suspected liver dysfunction during pregnancy. Liver stiffness represents a promising non-invasive tool for the assessment of patients with gestational hypertensive disorders.

13.
Am J Obstet Gynecol ; 227(5): 750.e1-750.e6, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35662633

ABSTRACT

BACKGROUND: The detection of increased nuchal translucency is crucial for the assessment risk of aneuploidies and other fetal anomalies. OBJECTIVE: This study aimed to investigate the ability of a transverse view of the fetal head to detect increased fetal nuchal translucency at 11 to 13 weeks of gestation. STUDY DESIGN: This was a prospective study enrolling a nonconsecutive series of women who attended our outpatient clinic from January 2020 to April 2021 for combined screening and were examined by operators certified by the Fetal Medicine Foundation. In each patient, nuchal translucency measurements were obtained both from a median sagittal view and from a transverse view. A second sonologist blinded to the results of the first examination obtained another measurement to assess intermethod and interobsever reproducibility. RESULTS: A total of 1023 women were enrolled. An excellent correlation was found between sagittal and transverse nuchal translucency measurements, with a mean difference of 0.01 mm (95% confidence interval, -0.01 to 0.02). No systematic difference was found between the 2 techniques. The inter-rater reliability (intraclass correlation coefficient, 0.957; 95% confidence interval, 0.892-0.983) and intrarater reliability (intraclass correlation coefficient, 0.976; 95% confidence interval, 0.941-0.990) of axial measurements were almost perfect. Transverse measurements of 3.0 mm identified all cases with sagittal measurements of ≥3.0 with a specificity of 99.7%; transverse measurements of >3.2 mm identified all cases with sagittal measurements of 3.5 mm with a specificity of 99.7%. The time required to obtain transverse nuchal translucency measurements was considerably shorter than for sagittal measurements, particularly when the fetus had an unfavorable position. CONCLUSION: When the sonogram is performed by an expert sonologist, the difference in nuchal translucency measurement obtained with a transverse or sagittal plane is minimal. Increased nuchal translucency can be reliably identified by using transverse views, and in some cases, this may technically be advantageous.

14.
J Med Ultrason (2001) ; 49(3): 405-413, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35705778

ABSTRACT

Hypertensive disorders are quite common, complicating about 10% of pregnancies, while preeclampsia occurs in 2-8% of cases. The most recognized etiopathogenetic factor for the development of preeclampsia is deficient remodeling of the spiral arteries during trophoblastic invasion. Recently, some authors speculated about the "cardiovascular origin of preeclampsia"; in particular, they postulate that placental dysfunction is not the primum movens of preeclampsia, but it could be caused by a failure of the maternal cardiovascular system to adapt to the pregnancy itself. Moreover, several studies have also shown that developing preeclampsia in pregnancy is associated with an increased risk of cardiovascular disease later in life. Due to the importance of this pathology, it would be crucial to have an effective screening in order to implement a prophylaxis; for this purpose, it could be useful to have an accurate and noninvasive device for the assessment of maternal hemodynamic variables. USCOM® (Ultrasonic Cardiac Output Monitor) is a noninvasive Doppler ultrasonic technology which combines accuracy, reproducibility, noninvasiveness, and a fast learning curve. Maternal hemodynamic evaluation is important in order to monitor the changes that the maternal organism encounters, in particular a reduction in blood pressure, a decrease in total peripheral resistances, and an increase in cardiac output, resulting in a hyperdynamic circle. These hemodynamic modifications are lacking in pregnancies complicated by preeclampsia. For these reasons, it is crucial to have a tool that allows these parameters to be easily evaluated in order to identify those women at higher risk of hypertensive complications and more severe outcomes.


Subject(s)
Hypertension, Pregnancy-Induced , Pre-Eclampsia , Female , Hemodynamics , Humans , Hypertension, Pregnancy-Induced/diagnostic imaging , Placenta , Pre-Eclampsia/diagnostic imaging , Pregnancy , Reproducibility of Results
16.
J Matern Fetal Neonatal Med ; 35(25): 9717-9723, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35272544

ABSTRACT

BACKGROUND: Alobar holoprosencephaly (HPE) is easily detected during a first-trimester screening examination, conversely, recognizing the lesser varieties may be difficult even in the second trimester. OBJECTIVES: To describe the imaging findings of a cohort of fetuses with holoprosencephaly (HPE) and to elucidate the appearances of the different anatomical varieties. MATERIALS AND METHODS: We reviewed medical records and stored images of pregnant women referred to our clinic because of a diagnosis or the suspicion of various forms of HPE. We reported the imaging characteristics, the presence of other associated anomalies, magnetic resonance findings, karyotype and autoptic examinations when available. RESULTS: Alobar forms show great distortion of normal brain anatomy, with a single ventricle detectable during the first trimester of pregnancy. Extracerebral, face and karyotype abnormalities are often associated. In semilobar and lobar forms the septum pellucidum is typically absent in axial planes, with fused frontal horns, while posterior fossa is often normal. At multiplanar neurosonogram, anomalies involving corpus callosum and cortex development can be detected. Face abnormalities are mild in lobar forms: receding forehead, various degrees of hypotelorism and the presence of a single central maxillary incisor are reported. CONCLUSIONS: The alobar forms are detectable since the first trimester, with a peculiar single ventricle and extremely frequent extracerebral and karyotype abnormalities. The semilobar and lobar forms are more challenging and the diagnosis is easily missed in a mid-trimester screening exam unless a careful evaluation of both cavum septi pellucidi and frontal horns as well is conducted.


Subject(s)
Holoprosencephaly , Female , Humans , Pregnancy , Holoprosencephaly/diagnostic imaging , Ultrasonography, Prenatal/methods , Pregnancy Trimester, Second , Septum Pellucidum/abnormalities , Fetus
17.
Eur J Obstet Gynecol Reprod Biol ; 270: 105-110, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35042176

ABSTRACT

OBJECTIVES: First trimester miscarriage is a multifactorial event. Various angiogenic factors have been proposed as possible early markers of non-viable pregnancies. The aim of the present study was to evaluate the systemic nitric oxide (NO) production in healthy early pregnancy and its possible role in first trimester miscarriage. STUDY DESIGN: We prospectively enrolled women referred to our Unit for elective termination of pregnancy, threatened abortion or missed abortion. Blood samples were taken for testing circulating NO plasma levels. Subsequently, all patients underwent 2-D ultrasonographic analysis and Color Doppler imaging to assess the pulsatility index of the uterine arteries. 3-D ultrasonographic and power Doppler analysis allowed a volumetric and vascular reconstruction of the placenta. During dilatation and vacuum aspiration, amniotic fluid was collected. RESULTS: Seventy-two patients were enrolled: 25 with elective termination of pregnancy (Group I); 17 with threatened abortion (Group II); 30 with missed abortion (Group III). Group II showed greater placental volume and lower uterine arteries PI than others. The plasma NO concentration resulted statistically higher in women with threatened abortion, while amniotic fluid NO concentration were higher in the viable pregnancies (Group I) than in the aborted fetuses (Group III). Plasma NO was inversely correlated with both mean arterial pressure and uterine artery PI and was positively correlated with amniotic fluid NO and CRL; amniotic fluid NO was positively correlated with placental Vascularization Index and Vascularization-Flow Index. CONCLUSION: Amniotic NO concentration was higher in viable pregnancies and positively related to Doppler 3D indices of vascularization and blood flow within the placenta. Further studies are needed to elucidate its role in first trimester miscarriage.


Subject(s)
Abortion, Induced , Abortion, Spontaneous , Abortion, Threatened , Abortion, Threatened/diagnostic imaging , Amniotic Fluid/diagnostic imaging , Female , Humans , Nitric Oxide , Pilot Projects , Placenta/blood supply , Pregnancy , Pregnancy Trimester, First , Uterine Artery/diagnostic imaging
18.
J Matern Fetal Neonatal Med ; 35(25): 6090-6096, 2022 Dec.
Article in English | MEDLINE | ID: mdl-33823732

ABSTRACT

BACKGROUND: Speckle tracking technology has been applied to assess ventricular deformation throughout the cardiac cycle. An electronic four dimensional probe that allows rapid acquisition of electronic spatio-temporal image correlation volumes (eSTIC) has been recently introduced. OBJECTIVES: The aim of our study was to investigate whether e-STIC acquisition improves deformation analyses reproducibility. STUDY DESIGN: We recruited fetuses between 20 and 40 weeks of gestation. We obtained a 2D video clip and an e-STIC volume of a four-chamber view. We focused on left ventricular global strain (LV-GS) and left ventricular ejection fraction (LV-FE). Intraobserver, interobserver and intermethod agreement were assessed by means of intraclass correlation coefficient (ICC) and illustrated by Bland-Altman plots. Systematic differences between measurements were assessed using a paired t-test. RESULTS: The mean difference between LV-GS values obtained with e-STIC and 2D analysis was -0.10 (95% CI -2.28, 2.08). No systematic differences were found between the two techniques for LV-GS values (p-value = .927). The mean difference between LV-FE values obtained with e-STIC and 2D analysis was 7.55 (95% CI 4.16, 10.95; p-value <.001). The inter-rater reliability of LV-GS was moderate-to-substantial for both e-STIC and 2D. The inter-rater reliability of LV-FE obtained via e-STIC was superior to that obtained via 2D analysis. The intra-rater reliability of LV-GS obtained with e-STIC was superior to that obtained with 2D analysis (ICC 0.857; 95% IC 0.761-0.917). The intra-rater reliability of LV-FE obtained via e-STIC was superior to that obtained via 2D analysis (ICC 0.647; IC 0.51-0.783). CONCLUSIONS: e-STIC seems to be a better technique than 2D analysis for intra-rater reliability of LV-GS. 4D acquisition might improve intrinsic limitations of speckle tracking echocardiography.


Subject(s)
Echocardiography, Three-Dimensional , Ventricular Function, Left , Female , Humans , Stroke Volume , Reproducibility of Results , Echocardiography/methods , Fetus , Electronics , Echocardiography, Three-Dimensional/methods
19.
J Matern Fetal Neonatal Med ; 35(25): 4942-4945, 2022 Dec.
Article in English | MEDLINE | ID: mdl-33455505

ABSTRACT

Cardiovascular changes that occur during pregnancy have been recently described and are matter of debate; during gestation we observe an increase in cardiac output and a reduction of peripheral total vascular resistance (TVR). In pregnancies complicated by hypertensive disorders, instead, these changes are lacking, with a persisting low cardiac output and high peripheral resistances. In this case report, we observed that in patients with chronic hypertension TVR are high, while the cardiac output is able to face the needs of pregnancy. The increase in TVR before the decision to deliver, due to bad blood pressure control despite therapy, may precede the alterations in blood tests (platelet decreasing and high liver enzymes). This data may be useful for monitoring patients with chronic hypertension and identifying those at higher risk of developing HELLP/severe preeclampsia.


Subject(s)
Hypertension , Pre-Eclampsia , Pregnancy , Humans , Female , Blood Platelets , Vascular Resistance/physiology , Hypertension/complications , Hypertension/therapy , Liver
20.
J Matern Fetal Neonatal Med ; 35(25): 5580-5586, 2022 Dec.
Article in English | MEDLINE | ID: mdl-33586584

ABSTRACT

BACKGROUND: Preeclampsia is a main obstetric disease and could be caused by the inability of the woman hemodynamic system to face the cardiovascular effort required by gestation. OBJECTIVE: The aim of the present study is to evaluate the correlation between maternal hemodynamic parameters detected by UltraSonic Cardiac Output Monitor (USCOM®) and ultrasound or biochemical parameters in women during the first-trimester screening of chromosomal abnormalities. METHODS: This was a prospective observational study with 162 women enrolled during the first-trimester ultrasound, recording demographic, biochemical and ultrasound data, including the pulsatility index of uterine arteries (UTPI). Hemodynamic indices were obtained using the USCOM® system. We also analyzed the outcomes of pregnancy of those women who delivered in our clinic. RESULTS: As for the correlation between biochemical and ultrasound parameters, pregnancy-associated plasma protein A (PAPP-A) relates inversely with the mean UTPI (rs -0.298, p < .001). We also reported a statistically significant correlation between the mean UTPI and the maternal haemodynamic parameters detected by USCOM® (higher values of mean UTPI are associated with lower values of indexed cardiac output, CO, and higher indexed peripheral resistances, TVR). When comparing women with higher UTPI and TVR or lower CO to patients who had regular values of these parameters, we noticed that between these groups there were significant differences in all the remaining hemodynamic parameters, including inotropy index and stroke volume, as well as in the biochemical values of PAPP-A. Analyzing postpartum data, if we combine the onset of hypertensive disorders and fetal growth restriction, the most predictive parameter is indexed TVR. CONCLUSION: Our study confirmed the correlation between PAPP-A and placental function, expressed through the determination of the pulsatility index of the uterine arteries. Moreover, we found a clear correlation between biochemical markers, placental function and maternal hemodynamics, since the first trimester of pregnancy. The inclusion of maternal hemodynamic evaluation could be useful in the screening protocols of preeclampsia. If we combine the onset of hypertensive disorders and of fetal growth restriction, the most predictive parameter is indexed total vascular resistances.


Subject(s)
Hypertension, Pregnancy-Induced , Pre-Eclampsia , Female , Humans , Pregnancy , Pregnancy Trimester, First , Fetal Growth Retardation/diagnostic imaging , Pregnancy-Associated Plasma Protein-A , Placenta , Hemodynamics
SELECTION OF CITATIONS
SEARCH DETAIL
...